TM 9-2320-366-20-5
17-29. M1089 30K WINCH PNEUMATIC MANIFOLD REPLACEMENT/REPAIR (CONT)
(10) Apply anti-seizing tape to threads of six fittings (13), tee
fitting (14), two plugs (15 and 16) and pipe nipple (17).
(11) Install two plugs (15), six fittings (13) and pipe nipple
(17) in M1089 30K winch pneumatic manifold (2).
(12) Install two plugs (16) and tee fitting (14) in regulating
valve (18).
(13) Position mounting bracket (19) on pipe nipple (17).
(14) Install regulating valve (18) on pipe nipple (17).
(15) Install mounting bracket (19) on M1089 30K winch
pneumatic manifold (2) with two screws (20).
e. Installation.
NOTE
Steps (1) and (2) requires the aid of an
assistant.
(1) Position M1089 30K winch pneumatic manifold assembly
(1) on 30K winch frame (2) with four washers (3), screws
(4), and self-locking nuts (5).
(2) Tighten four self-locking nuts (5) to 12-24 lb-in. (1-2
Nm).
NOTE
Install plastic cable ties as required.
(3) Install eight connector splices (6) between 16 wires (7).
(4) Cover eight connector splices (6) with electrical tape.
Change 1