TM 9-2320-366-20-5
17-29. M1089 30K WINCH PNEUMATIC MANIFOLD REPLACEMENT/REPAIR (CONT)
c. Cleaning/Inspection.
WARNING
Dry Cleaning Solvent (P-D-680) is TOXIC and flammable. Wear protective goggles and
gloves; use only in well ventilated area; avoid contact with skin, eyes, and clothes, and
do not breathe vapors. Keep away from heat or flame. Never smoke when using solvent;
the flashpoint for Type I Dry Cleaning Solvent is 100F (38C) and for Type II is 130F
(50C). Failure to comply may result in serious injury or death to personnel.
If personnel become dizzy while using cleaning solvent, immediately get fresh air and
medical help. If dry cleaning solvent contacts skin or clothes, flush with cold water. If dry
cleaning solvent contacts eyes, immediately flush eyes with water and get immediate
medical attention. Failure to comply may result in injury to personnel.
(1) Clean all metal parts with dry cleaning solvent.
NOTE
Replace any part that fails visual inspection.
(2) Check six fittings (1) for corrosion, pitting, cracks,
damaged or worn threads, and obstruction to ports.
(3) Check tee fitting (2) for corrosion, pitting, cracks,
damaged or worn threads, and obstruction to ports.
(4) Check two ports (3) in regulating valve (4) for obstruction
of passages.
(5) Check two plugs (5 and 6), eight plugs (7), and plug (8)
for corrosion, pitting, cracks, or damaged or worn
threads.
17-140
Change 1