TM 9-2320-366-20-5
d.
Assembly.
WARNING
Adhesives,
solvents,
and
sealing
compounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing. Keep away from open fire
and use in a well-ventilated area. If
adhesive, solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap and water. Failure
to comply may result in injury to
personnel.
(1) Apply sealing compound to threads of two plugs
(1), fitting (2), 90-degree fittings (3 and 4), and pipe
nipple (5).
NOTE
Install fittings in the same orientation
as noted during removal.
Install fittings, plugs, and pipe nipple
in steps (2) through (5) finger tight,
then wrench tighten an additional 2-3
turns.
(2) Install two plugs (1) in regulating valve (6).
(3) Install pipe nipple (5), fitting (2), and 90-degree
fitting (3) in shuttle valve (7).
(4) Install regulating valve (6) on pipe nipple (5).
(5) Install 90-degree fitting (4) in regulating valve (6).
17-147