TM 9-2320-366-20-5
(3) Connect M1089 30K winch test adapter on 90-degree
fitting (2).
(4) Install STE/ICE-R 0-1000 PSI pressure transducer in
M1089 30K winch test adapter.
(5) Connect hose (1) to M1089 30K winch test adapter.
(6) Start engine (TM 9-2320-366-10-1).
(7) Perform STE/ICE-R test #50.
(8) Turn knob (3) on regulating valve (4) clockwise until
pressure reads 65 psi on STE/ICE-R.
(9) Push in knob (3) on regulating valve (4).
(10) Shut down engine (TM 9-2320-366-10-1).
(11) Remove STE/ICE-R 0-1000 PSI transducer from M1089
30K winch test adapter.
(12) Disconnect hose (1) from M1089 30K winch test adapter.
(13) Disconnect M1089 30K winch test adapter from 90-
degree fitting (2).
Change 1
17-149