TM 9-2320-366-20-5
(66) Position terminal lugs TL61 (94) and TL171 (95) on
terminal block terminal (96) with washer (69), lockwasher
(68), and nut (67).
(67) Remove dust cap (97) from connector J106 (98).
(68) Remove nut (99), dust cap lanyard (100), and connector
J106 (98) from chemical detection unit mounting bracket
(101).
(69) Disconnect air filter restriction gauge hose (102) from air
flow sensor (103).
NOTE
Perform steps (70) through (104) on all
models except M1093/M1094.
(70) Loosen clamp (104) on particle extraction hose (105).
(71) Remove particle extraction hose (105) from adapter
(106).
20-237