TM 9-2320-366-20-5
This task covers:
a. Removal
c. Follow-On Maintenance
b. Installation
INITIAL SETUP
Equipment Conditions
Materials/Parts
Engine shut down (TM 9-2320-366-10-1).
Tools and Special Tools
a. Removal.
WARNING
Hydraulic fluid (MIL-L-5606) is TOXIC.
Wear protective goggles and gloves; use
only in well ventilated area; avoid contact
with skin, eyes, and clothes. Skin and
clothing that come in contact with
hydraulic oil should be washed
immediately. Saturated clothing should
be removed immediately.
Failure to
comply may result in injury to personnel.
(1) Remove two plugs (1) from hydraulic manifold (2).
(2) Remove two preformed packings (3) from plugs (1).
Discard preformed packings and plugs.
(3) Remove two retainers (4), filters (5), and springs (6) from
hydraulic manifold (2). Discard retainers, filters, and
springs.