TM 9-2320-366-20-5
(24) Install preformed packing (49) on plug (50).
(25) Position plug (50) in hydraulic manifold (2).
(26) Tighten plug (50) to 13 lb-ft (18 Nm).
WARNING
Adhesives, solvents, and sealing com-
pounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing. Keep away from open fire
and use in a well-ventilated area. If
adhesive, solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap and water. Failure
to comply may result in injury to
personnel.
(27) Apply sealing compound to threads of plug (51).
(28) Position preformed packing (52), check valve (53),
setscrew (54), and plug (51) in hydraulic manifold (2).
(29) Tighten plug (51) to 21 lb-ft (28 Nm).
(30) Install breather cap (55) in hydraulic manifold (2).
(31) Apply antiseize compound to four air fittings (56).
(32) Install four air fittings (56) in hydraulic manifold (2).
(33) Install eight preformed packings (57) on fittings (58).
(34) Install eight fittings (58) in hydraulic manifold (2).
(35) Install two preformed packings (59) on 45-degree fittings
(60).
(36) Install two 45-degree fittings (60) in hydraulic manifold
(2).
Change 1