TM 9-2320-366-20-4
11-25. SERVICE GLADHAND TWO-WAY CHECK VALVE REPLACEMENT (CONT)
(5) Position service gladhand two-way check valve (4) on
front fender (5) with washer (6), screw (7), and self-
locking nut (8).
(6) Tighten self-locking nut (8) to 13-16 lb-ft (18-22 Nm).
(7) Connect air hose (9) to 45-degree fitting (3).
(8) Connect air hose (10) to 90-degree fitting (2).
(9) Connect two air hoses (11) to branch tee fitting (1).
c. Follow-On Maintenance.
(1) Lower cab (TM 9-2320-366-10-1).
(2) Install windshield washer reservoir and pump (para 18-
2).
(3) Start engine (TM 9-2320-366-10-1) and allow air
pressure to build to normal operating pressure.
(4) Check around service gladhand two-way check valve for
air leaks.
(5) Shut down engine (TM 9-2320-366-10-1).
End of Task.
11-160
Change 1