TM 9-2320-366-20-4
NOTE
Note orientation of fittings prior to removal.
(5) Remove 45-degree fitting (6) from service gladhand two-
way check valve (8).
(6) Remove 90-degree fitting (4) from service gladhand two-
way check valve (8).
(7) Remove branch tee fitting (2) from service gladhand two-
way check valve (8).
b. Installation.
WARNING
Adhesives, solvents, and sealing com-
pounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing. Keep away from open fire
and use in a well-ventilated area. If
adhesive, solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap and water. Failure
to comply may result in injury to
personnel.
(1) Apply antiseize compound to threads of branch tee fitting
(1), 90-degree fitting (2), and 45-degree fitting (3).
(2) Install branch tee fitting (1) in service gladhand two-way
check valve (4).
(3) Install 90-degree fitting (2) in service gladhand two-way
check valve (4).
(4) Install 45-degree fitting (3) in service gladhand two-way
check valve (4).
11-159