TM 9-2320-366-20-5
(4) Remove terminal lug TL6 (6) from dust boot (7).
NOTE
Retain 24 vdc and 12 vdc cable assemblies
for future installation.
(5) Remove three screws (8), washers (9), clamps (10), 24
vdc cable (11), and 12 vdc cable (12) from air inlet
manifold (13).
(6) Remove three clamps (10) from 24 vdc cable (11) and
12 vdc cable (12).
(7) Remove self-locking nut (14) and washer (15) from
CAUTION
Ensure pulley does not contact wires,
terminal lugs, or terminal screws on front
in damage to equipment.
(8) Position pulley (17) on alternator (16) with washer (15)
and self-locking nut (14).
(9) Position pulley (17) in vise.
(10) Tighten self-locking nut (14) to 106-130 lb-ft (144-176
Nm).
(11) Remove pulley (17) from vise.
20-228
Change 1