TM 9-2320-366-20-4
b. Installation.
WARNING
Adhesives, solvents, and sealing com-
pounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing. Keep away from open fire
and use in a well-ventilated area. If
adhesive, solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap and water. Failure
to comply may result in injury to
personnel.
(1) Apply antiseize compound to threads of branch tee fitting
(1), two 90-degree fittings (2), and run tee fitting (3).
(2) Install branch tee fitting (1) in inversion valve (4).
(3) Install two 90-degree fittings (2) in inversion valve (4).
(4) Install run tee fitting (3) in inversion valve (4).
(5) Position inversion valve (4) on panel (5) with two
washers (6), screws (7), and self-locking nuts (9).
(6) Tighten two self-locking nuts (9) to 14-18 lb-ft (20-24
Nm).
Change 1
11-79