TM 9-2320-366-20-4
b. Installation.
WARNING
Adhesives, solvents, and sealing com-
pounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing. Keep away from open fire
and use in a well-ventilated area. If
adhesive, solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap and water. Failure
to comply may result in injury to
personnel.
(1) Apply antiseize compound to threads of plug (1), two 90-
degree fittings (2), 90-degree fitting (4), two tee fittings
(5), fittings (6), and 90-degree fittings (7).
(2) Install plug (1) in anti-compounding relay valve (8).
(3) Install two 90-degree fittings (2) in anti-compounding
(4) Deleted.
(5) Install 90-degree fitting (4) in anti-compounding relay
valve (8).
(6) Install two tee fittings (5), fittings (6) and 90-degree
fittings (7) in anti-compounding relay valve (8).
(7) Position anti-compounding relay valve (8) on panel (9)
with two washers (10), screws (11), and self-locking nuts
(13).
(8) Tighten two self-locking nuts (13) to 14-18 lb-ft (20-24
Nm).