TM 9-2320-366-20-4
b. Installation.
(1) Install collet nut (1) on front air chamber (2) to bottom of
threads.
WARNING
Adhesives, solvents, and sealing com-
pounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing. Keep away from open fire
and use in a well-ventilated area. If
adhesive, solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap and water. Failure
to comply may result in injury to
personnel.
(2) Apply sealing compound to threads of front air chamber
(2).
WARNING
Ensure air chamber is caged prior to
installation. Failure to comply may result
in injury to personnel.
CAUTION
Ensure front air chamber is installed with
fitting ports positioned up. Failure to
comply may result in damage to
equipment.
(3) Install front air chamber (2) in plunger housing (3) until
it bottoms.
CAUTION
Loosen front air chamber no more than one
full turn. Failure to comply may result in
damage to equipment.
(4) Loosen front air chamber (2) until fitting ports are up.
(5) Tighten collet nut (1) against plunger housing (3).
11-41