TM 9-2320-366-20-4
7-124. M1090/M1094 DUMP CABLE ASSEMBLY REPLACEMENT
This task covers:
a. Removal
c. Follow-On Maintenance
b. Installation
INITIAL SETUP
Equipment Conditions
Materials/Parts
Dump body raised to maintenance position (TM 9-
Dispenser, Pressure Adhesive Sensitive Tape
2320-366-10-1).
Batteries disconnected (para 7-57).
Tools and Special Tools
a. Removal.
(1) Disconnect connector P172 (1) from connector J172 (2).
(2) Remove four nuts (3), lockwashers (4), screws (5), and
connector J172 (2) from connector plate (6). Discard
lockwashers.
(3) Remove four nuts (7), lockwashers (8), screws (9), and
connector plate (6) from crossmember (10). Discard
lockwashers.
(4) Disconnect connector P25 (11) from dump body switch
connector (12).
(5) Remove self-locking nut (13), screw (14), washer (15),
and clamp (16) from crossmember (10). Discard self-
locking nut.
(6) Remove clamp (16) from dump cable assembly (17).