TM 9-2320-366-20-4
(7) Remove five self-locking nuts (18), screws (19), washers
(20), and clamps (21) from frame rail (22). Discard self-
locking nuts.
(8) Remove five clamps (21) from dump cable assembly
(17).
NOTE
Tag wires and connection points prior to
disconnecting.
(9) Loosen two captive screws (23) in connectors L8 (24)
and L9 (25).
(10) Remove connectors L8 (24) and L9 (25) from two
(11) Loosen captive screw (27) in connector L7 (28).
(12) Remove connector L7 (28) from solenoid (29).
7-609