TM 9-2320-366-20-4
7-124. M1090/M1094 DUMP CABLE ASSEMBLY REPLACEMENT (CONT)
b. Installation.
(1) Install connector L7 (1) on solenoid (2).
(2) Tighten captive screw (3) in connector L7 (1).
(3) Install connectors L8 (4) and L9 (5) on two solenoids (6).
(4) Tighten two captive screws (7) in connectors L8 (4) and
L9 (5).
(5) Install five clamps (8) on dump cable assembly (9).
(6) Position five clamps (8) on frame rail (10) with five
washers (11), screws (12), and self-locking nuts (13).
(7) Tighten five self-locking nuts (13) to 96-120 lb-in. (11-14
Nm).
(8) Install clamp (14) on dump cable assembly (9).
(9) Position clamp (14) on crossmember (15) with washer
(16), screw (17), and self-locking nut (18).
(10) Tighten self-locking nut (18) to 96-120 lb-in. (11-14 Nm).
(11) Connect dump body switch connector (19) to connector
P25 (20).
7-610