TM 9-2320-366-20-4
7-123. M1089 TELESCOPE OUT SOLENOID CABLE REPLACEMENT (CONT)
b. Installation.
(1) Install telescope out solenoid cable (1) in compression
nut (2), washer (3), and connector (4).
(2) Install compression nut (2) on connector (4).
(3) Install quick disconnect terminal (5) on black wire (6).
(4) Install terminal lug (7) on white wire (8).
(5) Install quick disconnect terminal (5) on ground strip (9)
position 13.
(6) Install terminal lug (7) on terminal block (10) position 11
with screw (11).
(7) Apply varnish to quick disconnect terminal (5) and
terminal lug (7).