TM 9-2320-366-20-5
23-7. SHUTTLE VALVE REPLACEMENT (CONT)
b. Installation.
WARNING
Adhesives, solvents, and sealing com-
pounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing. Keep away from open fire
and use in a well-ventilated area. If
adhesive, solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap and water. Failure
to comply may result in injury to
personnel.
(1) Apply antiseize compound to threads of adapter (1) and
adapter (2).
(2) Install shuttle valve (3) on adapter (1).
(3) Install adapter (2) in shuttle valve (3).
(4) Apply antiseize compound to threads of 90-degree fitting
(4).
(5) Install 90-degree fitting (4) on shuttle valve (3).
(6) Connect air hose (5) to 90-degree fitting (4).
c. Follow-On Maintenance.
(2) Start engine (TM 9-2320-366-10-1).
(3) Check for air leaks around shuttle valve and inversion
valve.
(4) Shut down engine (TM 9-2320-366-10-1).
End of Task.