23-8. M1090/M1094 MANUAL OVERRIDE THREE-WAY VALVE REPLACEMENT (CONT)
(4) Remove two nuts (9), lockwashers (10), screws (11), and
NOTE
Note orientation of fittings prior to removal.
(5) Remove two 90-degree fittings (2) from valve (12).
(6) Remove fitting (4) from valve (12).
b. Installation.
WARNING
Adhesives, solvents, and sealing com-
pounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing. Keep away from open fire
and use in well-ventilated area.
If
adhesive, solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap and water. Failure
to comply may result in injury to
personnel.
(1) Apply antiseize compound to threads of two 90-degree
fittings (1) and fitting (2).
(2) Install two 90-degree fittings (1) in valve (3).
(3) Install fitting (2) in valve (3).
23-24