22-4. M1089 WARNING LIGHTS CABLE REPLACEMENT (CONT)
(8) Install clamp (20) on M1089 warning lights cable
assembly (2).
(9) Position clamp (20), clamp half (21), and clamp half (22)
on cab (4) with washer (23), screw (24), washer (25),
washer (26), and self-locking nut (27).
(10) Tighten self-locking nut (27) to 26-32 lb-ft (35-43 Nm).
(11) Connect connector P62A (28) to connector J62 (29).
c. Follow-On Maintenance.
End of Task.