20-55. 200 AMP TERMINAL BLOCK TO REVERSE POLARITY RELAY 12 VDC BATTERY
CABLE REPLACEMENT (CONT)
NOTE
Install plastic cable ties as required.
(4) Install convoluted tubing (8) on 200 amp terminal block
to reverse polarity relay 12 vdc battery cable (1) and 200
amp terminal block to reverse polarity relay 12 vdc load
cable (9).
(5) Install dust boot (10) on 200 amp terminal block to
reverse polarity relay 12 vdc battery cable (1).
(6) Position terminal lug TL173 (11) on reverse polarity relay
12 VDC BAT terminal (12) with lockwasher (13), and nut
(14).
(7) Tighten nut (14) to 120 lb-in. (14 Nm).
(8) Position dust boot (10) on terminal lug TL173 (11).
(9) Position turbocharger intake hose (15) on intake air
cleaner boot (16) with clamp (17).
(10) Tighten clamp (17) to 36-48 lb-in. (4-5 Nm).
c. Follow-On Maintenance.
(1) Connect batteries (para 7-57).
(2) Raise spare tire (TM 9-2320-366-10-2).
(3) Start engine (TM 9-2320-366-10-1).
(4) Check VOLTS gage for charge indication (TM 9-2320-
366-10-1).
(5) Shut down engine (TM 9-2320-366-10-1).
End of Task.