TM 9-2320-366-20-5
20-51. 200 AMP
TERMINAL BLOCK TO
REVERSE POLARITY RELAY 24
VDC LOAD
CABLE REPLACEMENT
This task covers:
a. Removal
c. Follow-On Maintenance
b. Installation
INITIAL SETUP
Equipment Conditions
Materials/Parts
Spare tire lowered (TM 9-2320-366-10-2).
Cab raised (TM 9-2320-366-10-1).
Batteries disconnected (para 7-57).
Tools and Special Tools
a. Removal.
(1) Loosen clamp (1) on turbocharger intake hose (2).
(2) Remove turbocharger intake hose (2) from intake air
cleaner boot (3).
(3) Lift dust boot (4) on terminal lug TL168 (5).
NOTE
Remove plastic cable ties as required.
(4) Remove nut (6), lockwasher (7), and terminal lug TL168
(5) from reverse polarity relay 24 VDC LOAD terminal
(8). Discard lockwasher.
(5) Remove dust boot (4) from 200 amp terminal block to
reverse polarity relay 24 vdc load cable (9).