TM 9-2320-366-20-5
19-20. M1089 HYDRAULIC TANK AND MANIFOLD ASSEMBLY REPAIR (CONT)
(3) Install two sections of resilient mounts (7) in each side
of support plate (8).
(4) Position support plate (8) on base plate (9) with two
screws (10), washers (11), and self-locking nuts (12).
(5) Tighten two self-locking nuts (12) to 76-84 lb-ft (103-
114 Nm).
(6) Install support plate (8) on rear bracket (13) with four
washers (14) and screws (15).
CAUTION
Holes in bolts must align towards center of
sight level indicator. Failure to comply may
result in damage to equipment.
(6.1) Matchmark bolt (16) so that mark aligns with hole in
shank of bolt.
(7) Position two gaskets (16) and sight level indicator (17)
on hydraulic tank (18) with two washers (19) and
screws (20).
(8) Install two nuts (21) on screws (20) with matchmarks
aligned.
Change 1