TM 9-2320-366-20-5
19-20. M1089 HYDRAULIC TANK AND MANIFOLD ASSEMBLY REPAIR (CONT)
WARNING
Adhesives, solvents, and sealing com-
pounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing. Keep away from open fire
and use in a well-ventilated area. If
adhesive, solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap and water. Failure
to comply may result in injury to
personnel.
(15) Apply antiseize compound to threads of the hydraulic
tank nipple (30).
(16) Install 90-degree fitting (31) on hydraulic tank (18).
(17) Apply antiseize compound to threads of adapter fitting
(32).
(18) Install adapter fitting (32) on 90-degree fitting (31).
(19) Apply antiseize compound to threads of manifold (33).
(20) Install manifold (33) on hydraulic tank (18) with
matchmarks aligned.
(21) Apply antiseize compound to threads of magnetic plug
(34).
(22) Install magnetic plug (34) in hydraulic tank (18).
19-110