TM 9-2320-366-20-5
WARNING
Adhesives, solvents, and sealing com-
pounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing. Keep away from open fire
and use in a well-ventilated area. If
adhesive, solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap and water. Failure
to comply may result in injury to
personnel.
(10) Apply antiseize compound to two 45-degree fittings (6).
(11) Install two 45-degree fittings (6) on manifold (5).
(12) Apply antiseize compound to threads of 45-degree fitting
(2).
(13) Install 45-degree fitting (2) and 90-degree fitting (1) on
manifold (5) with matchmarks aligned.
f. Hydraulic Tank Assembly.
CAUTION
Metal side of cushion must be against
resilient mount. Failure to comply may result
in damage to equipment.
(1) Position two cushions (1) and resilient mounts (2) on
front brackets (3) with eight screws (4), spacers (5), and
self-locking nuts (6).
(2) Tighten eight self-locking nuts (6) to 144-192 lb-in. (16-
22 Nm).