19-19. HYDRAULIC RESERVOIR AND BRACKET REPLACEMENT (CONT)
WARNING
Adhesives, solvents, and sealing com-
pounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing. Keep away from open fire
and use in a well-ventilated area. If
adhesive, solvent, or sealing compound
gets on skin or clothing, washer
immediately with soap and water. Failure
to comply may result in injury to
personnel.
(14) Apply sealing compound to threads of nut (20).
(15) Position nut (20) on strap (12).
(16) Tighten nut (20) to 42-52 ft-lb (57-71 Nm).
(17) Connect hose (21) to fitting (19).
(18) Connect hose (22) to 90-degree fitting (16).
NOTE
Perform steps (19) through (21) on models
M1090 and M1094.
(19) Position guard support bracket (23) on bracket (1)
with two bolts (24) and self-locking nuts (25).
(20) Position two bolts (24) and self locking nuts (25) in
guard support bracket (23) and stone guard (26).
(21) Tighten four self-locking nuts (25) to 20-24 lb-ft (27-
33 Nm).
e. Follow-On Maintenance.
End of Task.