TM 9-2320-366-20-5
18-6. WINDSHIELD WASHER HOSES AND CONNECTOR REPLACEMENT (CONT)
(13) Remove bottom end of hose (7) from lockwire.
(14) Disconnect three hoses (7) from wye splitter (15).
(15) Disconnect three hoses (7) from check valve (16).
b. Installation.
(1) Connect three hoses (1) to check valve (2).
(2) Connect three hoses (1) to wye splitter (3).
NOTE
Steps (3) and (4) require the aid of an
assistant.
(3) Route three hoses (1) through dashboard (4).
NOTE
All three connectors and hoses are installed
the same way. Center connector and hose
shown.
(4) Install three connectors (5) and nuts (6) in cab (7).
(5) Connect three hoses (1) to three connectors (5).
18-20