TM 9-2320-366-20-5
d. Assembly.
NOTE
Cathode side of rectifier (side with band) is
positioned toward positive lead (yellow) and
the opposite end positioned toward negative
ground lead (black).
(1) Position rectifier (1) on electrical leads (2).
(2) Solder rectifier (1) to electrical leads (2).
(3) Install insulation sleeving (3) over electrical leads
(2) and shrink insulation sleeving.
WARNING
Adhesives,
solvents,
and
sealing
compounds can burn easily, can give
off harmful vapors, and are harmful to
skin and clothing. Keep away from
open fire and sue well-ventilated area. If
adhesive,
solvent,
or
anti-seize
compound gets on skin or clothing,
wash immediately with soap and water.
Failure to comply may result in injury to
personnel.
NOTE
Apply sealant to first two to five threads of
fittings and plugs prior to installation.
(3.1) Apply sealant to threads of plug (4) fittings (6)
And fittings (7)
(4) Install plug (4) in valve manifold assembly (5).
(5) Install fitting (6) in valve manifold assembly (5).
(6) Install ten fittings (7) in valve manifold assembly (5).
(6.1) Tighten plug (4) fitting (6) and fittings (7) 2-3 turns
with wrench.
Change 2