TM 9-2320-366-20-5
17-32. 30K WINCH VALVE MANIFOLD ASSEMBLY REPLACEMENT/REPAIR (CONT)
(4) Remove insulation sleeving (5) from electrical
leads (6).
CAUTION
Care must be taken when removing
rectifiers. Failure to comply may cause
damage to electrical leads.
(5) Remove rectifier (7) from electrical leads (6).
c. Cleaning/Inspection.
WARNING
Dry Cleaning Solvent (P-D-680) is TOXIC and flammable. Wear protective goggles and gloves;
use only in well ventilated area; avoid contact with skin, eyes, and clothes, and do not
breathe vapors. Keep away from heat or flame. Never smoke when using solvent; the
flashpoint for Type I Dry Cleaning Solvent is 100F (38C) and for Type II is 130F (50C).
Failure to comply may result in serious injury or death to personnel.
If personnel become dizzy while using cleaning solvent, immediately get fresh air and medical
help. If dry cleaning solvent contacts skin or clothes, flush with cold water. If dry cleaning
solvent contacts eyes, immediately flush eyes with water and get immediate medical attention.
Failure to comply may result in injury to personnel.
(1) Clean all metal parts with dry cleaning solvent.
NOTE
Replace any part that fails visual inspection.
(2) Check fittings (1) for cracks, corrosion,pitting,
damaged or worn threads, and obstruction to parts.
(3) Check plug (2) for cracks, corrosion, pitting,
damaged or worn threads.
(4) Check valve manifold (3) for cracks, corrosion,
pitting, damaged or worn threads, and obstruction to
parts.
17-160
Change 2