TM 9-2320-366-20-5
(4) Remove 90 degree fitting (2) from air chamber (8).
b. Installation.
WARNING
Adhesives, solvents, and sealing com-
pounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing. Keep away from open fire
and use in a well-ventilated area. If
adhesive, solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap and water. Failure
to comply may result in injury to
personnel.
(1) Apply antiseize compound to threads of 90-degree fitting
(1).
(2) Position 90-degree fitting (1) in air chamber (2).
(3) Tighten 90-degree fitting (1) approximately 2 1/2 turns
past hand tight.
17-83