(8) Remove two self-locking nuts (10), screws (11), washers
(12), and booster valve (6) from bracket (13). Discard
self-locking nuts.
b. Installation.
(1) Position booster valve (1) on bracket (2) with two
washers (3), screws (4), and self-locking nuts (5).
(2) Tighten two self-locking nuts (5) to 14-18 lb-ft (20-24
Nm).
WARNING
Adhesives, solvents, and sealing com-
pounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing. Keep away from open fire
and use in a well-ventilated area. If
adhesive, solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap and water. Failure
to comply may result in injury to
personnel.
(3) Apply antiseize compound to threads of plug (6).
(4) Install plug (6) in booster valve (1).
11-87