TM 9-2320-366-20-4
7-146. DUMP SWITCH BRACKET AND JUMPER CABLE REPLACEMENT
This task covers:
a. Removal
c. Follow-On Maintenance
b. Installation
INITIAL SETUP
Equipment Conditions
Materials/Parts
Batteries disconnected (para 7-57).
Dispenser, Pressure Sensitive Adhesive Tape (Item 20,
Tools and Special Tools
Personnel Required
(2)
a. Removal.
(1) Remove two screws (1) and washers (2) from dump
switch bracket (3).
(2) Lift dump switch bracket (3) outward from instrument
panel (4) to gain access.
NOTE
Tag electrical connectors and connection
points prior to removal.
All rocker switches are removed the same
way. DUMP BED UP/DOWN switch
shown.
(3) Lift tab (5) on connector P911 (6).
(4) Disconnect connector P911 (6) from DUMP BED
UP/DOWN switch (7).
(5) Disconnect connector P911A (8) from DUMP BED
UP/DOWN switch (7).
Change 2