NOTE
Tag wires and connection points prior to
disconnecting.
(4) Remove three screws (6) from terminal block (7)
positions 1, 17, and 19.
(5) Disconnect quick disconnect terminal (8) from ground
strip (9) position 5.
(6) Remove quick disconnect terminal (8) from green wire
(10).
(7) Remove terminal lugs (11, 12, and 13) from black wire
(14), red wire (15), and white wire (16).
(8) Loosen two screws (17) on clamp (18).
(9) Remove compression nut (19) from connector (20).
(10) Remove overload lockout cable (21) from compression
nut (19).
7-579