TM 9-2320-366-20-4
NOTE
Tag wires and connection points prior to
disconnecting.
(4) Remove three screws (6) from terminal block (7)
positions 3, 4, and 5.
(5) Disconnect quick disconnect terminal (8) from ground
strip (9) position 16.
(6) Remove quick disconnect terminal (8) from green wire
(10).
(7) Remove terminal lugs (11, 12, and 13) from white wire
(14), red wire (15), and black wire (16).
(8) Loosen nut (17) on clamp (18).
(9) Loosen two screws (19) on clamp (20).
(10) Remove compression nut (21) from connector (22).
(11) Remove crane power cable (23) from connector (22),
compression nut (21), and clamp (20).
(12) Remove crane power cable (23) from clamp (18).
7-451