TM 9-2320-392-10-2
ELECTRICAL SYSTEM TROUBLESHOOTING - Continued 0080 00
ELECTRICAL SYSTEM Continued
Table 3. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
22. COOLANT TEMP
Does WATER TEMP
1. Start engine (WP 0018 00).
INDICATOR
gage read below
ILLUMINATES
216F (102C) when
2. Check to see if WATER TEMP
COOLANT TEMP
gage reads below 216F
indicator illuminates?
(102C) when COOLANT TEMP
Indicator illuminates.
3. If WATER TEMP gage reads
above 216F (102C) when
COOLANT TEMP indicator
illuminates, perform Cooling
System Troubleshooting (WP
Overheats).
4. If WATER TEMP gage reads
below 216F (102C) when
COOLANT TEMP indicator
illuminates, notify Field
Maintenance.
5. Shut down engine (WP 0016
00).
23. CTIS OVERSPEED
1. Check to see if LAMP
1. If LAMP TEST switch does not
INDICATOR DOES
TEST switch
illuminates CTIS OVERSPEED
NOT ILLUMINATE
illuminates CTIS
indicator, go to test 2 of this
OVERSPEED indicator
malfunction.
(WP 0018 00).
2. If LAMP TEST switch
illuminates CTIS OVERSPEED
indicator, notify Field
Maintenance.
0080 00-35