TM 9-2320-392-10-2
ELECTRICAL SYSTEM TROUBLESHOOTING - Continued 0080 00
ELECTRICAL SYSTEM Continued
Table 3. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
15. AUDIBLE ALARM
5. If audible alarm does not
DOES NOT
operate from low air pressure,
OPERATE WHEN
perform Malfunction 14
TROOP
(Audible Alarm Does Not
TRANSPORT
Operate).
ALARM SWITCH
IS TURNED ON -
Continued
6. If audible alarm operates from
low air pressure, notify Field
Maintenance.
3. Check to see if
1. Start engine (WP 0018 00,
audible alarm
Cold Engine Start).
operates when troop
transport alarm
switch is turned on.
2. Allow engine to run until air
tanks are above 75 PSI.
3. Check to see if troop transport
alarm is audible (WP 0012 00).
4. If audible alarm does not
operate when troop transport
alarm switch is turned on,
notify Field Maintenance.
16. INSTRUMENT
Notify Field Maintenance.
PANEL SWITCH
DOES NOT
ILLUMINATE
17. INSTRUMENT
Check to see if any
1. If no instrument panel gage
PANEL GAGE DOES
instrument panel
illuminates, perform
NOT ILLUMINATE
gage illuminates (WP
Malfunction 18 (Auxiliary
0018 00).
Panel, Personnel Heater, and
Instrument Panel Do Not
Illuminate).
2. If one instrument panel gage
does not illuminate, notify Field
Maintenance
0080 00-32