TM 9-2320-392-10-2
ELECTRICAL SYSTEM TROUBLESHOOTING - Continued 0080 00
ELECTRICAL SYSTEM Continued
Table 3. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
14. AUDIBLE ALARM
2. If lamp test switch illuminates
DOES NOT
lighted indicator display, go to
OPERATE -
test 4 of this malfunction.
Continued
4. Do radio, electrical
1. Check to see if electrical gages
gages, and starter
and starter pushbutton operate
pushbutton operate?
(WP 0018 00).
1. If electrical gages and starter
pushbutton do not operate,
perform Malfunction 164
(Audible Alarm, Radio,
Electrical Gages, and Starter
Pushbutton Do Not Operate).
2. If electrical gages and starter
pushbutton operate, notify
Field Maintenance.
15. AUDIBLE ALARM
1. Check to see if lamp
1. If lamp test switch does not
DOES NOT
test switch
illuminate lighted indicator
OPERATE WHEN
illuminates lighted
display, go to test 3 of this
TROOP
indicator display (WP
malfunction.
TRANSPORT
0018 00).
ALARM SWITCH IS
TURNED ON
2. If lamp test switch illuminates
lighted indicator display, go to
test 2 of this malfunction.
2. Check to see if
1. Drain air tanks (WP 0018 00).
audible alarm sounds
from low air
pressure.
2. Position master power switch
to on (WP 0004 00).
3. Check to see if audible alarm
sounds from low air pressure.
4. Position master power switch
to off (WP 0004 00).
0080 00-31