TM 9-2320-392-10-2
ELECTRICAL SYSTEM TROUBLESHOOTING - Continued 0080 00
ELECTRICAL SYSTEM Continued
Table 3. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
24. CHEMICAL DETECT
3. Check circuit breaker
INDICATOR DOES
CB30 in PCB to see if
NOT ILLUMINATE -
it is tripped.
Continued
2. If circuit breaker CB30 has
tripped, push in to reset.
3. Position master power switch
to on (WP 0004 00).
4. Check to see if circuit breaker
CB30 has tripped again.
5. Position master power switch
to off (WP 0004 00).
6. If circuit breaker CB30 has
tripped again, notify Field
Maintenance.
7. If circuit breaker CB30 did not
trip again, go to test 6 of this
malfunction.
0080 00-37