TM 9-2320-366-20-5
20-49. 200 AMP TERMINAL BLOCK TO REVERSE POLARITY RELAY 12 VDC LOAD
CABLE REPLACEMENT (CONT)
b. Installation.
(1) Position 200 amp terminal block to reverse polarity relay
12 vdc load cable (1) on rear side of front lifting beam
(2).
(2) Position terminal lug TL172 (3) on terminal block terminal
(4) with washer (5), lockwasher (6), and nut (7).
(3) Tighten nut (7) to 15-19 lb-ft (21-25 Nm).
NOTE
Install plastic cable ties as required.
(4) Install convoluted tubing (8) on 200 amp terminal block
to reverse polarity relay 12 vdc load cable (1) and 200
amp terminal block to reverse polarity relay 12 vdc
battery cable (9).
(5) Install dust boot (10) on 200 amp terminal block to
reverse polarity relay 12 vdc load cable (1).
(6) Position terminal lug TL174 (11) on reverse polarity relay
(12) with lockwasher (13), and nut (14).
(7) Tighten nut (14) to 108-132 lb-in. (12-15 Nm).
(8) Position dust boot (10) on terminal lug TL174 (11).
20-284