TM 9-2320-366-20-5
NOTE
Remove plastic cable ties as required.
(3) Lift dust boot (4) on terminal lug TL174 (5).
(4) Remove nut (6), lockwasher (7), and terminal lug TL174
(5) from reverse polarity relay (8). Discard lockwasher.
(5) Remove dust boot (4) from 200 amp terminal block to
reverse polarity relay 12 vdc load cable (9).
(6) Remove convoluted tubing (10) from 200 amp terminal
block to reverse polarity relay 12 vdc load cable (9) and
200 amp terminal block to reverse polarity relay 12 vdc
battery cable (11).
(7) Remove nut (12), lockwasher (13), washer (14), and
terminal lug TL172 (15) from terminal block terminal (16).
Discard lockwasher.
(8) Remove 200 amp terminal block to reverse polarity relay
12 vdc load cable (9) from rear side of front lifting beam
(17).
20-283