TM 9-2320-366-20-5
(9) Lift dust boot (16) on terminal lug TL168 (17).
(10) Remove nut (18), lockwasher (19), and terminal lug
TL168 (17) from reverse polarity relay 24V BAT terminal
(20). Discard lockwasher.
(11) Lift dust boot (21) on terminal lug TL169 (22).
(12) Remove nut (23), lockwasher (24), and terminal lug
TL169 (22) from reverse polarity relay 24V LOAD
terminal (25). Discard lockwasher.
NOTE
Note orientation of reverse polarity relay prior
to removal.
(13) Remove two self-locking nuts (26), screws (27), and
reverse polarity relay (28) from brackets (29 and 30).
Discard self-locking nuts.
d. Installation (M1093/M1094).
(1) Position reverse polarity relay (1) on brackets (2 and 3)
with two screws (4) and self-locking nuts (5).
(2) Tighten two self-locking nuts (5) to 22-27 lb-ft (31-37
Nm).
20-275