TM 9-2320-366-20-5
20-47. 200 AMP REVERSE POLARITY RELAY REPLACEMENT (CONT)
c. Removal (M1093/M1094).
(1) Loosen clamp (1) on air compressor intake hose (2).
(2) Remove air compressor intake hose (2) from intake air
cleaner boot (3).
(3) Loosen clamp (4) on intake air cleaner boot (3).
(4) Remove intake air cleaner boot (4) from intake air
cleaner housing (5).
NOTE
Tag cables and connection points prior to
disconnecting.
Remove plastic cable ties as required.
(5) Lift dust boot (6) on terminal lug TL173 (7).
(6) Remove nut (8), lockwasher (9), and terminal lug TL173
(7) from reverse polarity relay 12V BAT terminal (10).
Discard lockwasher.
(7) Lift dust boot (11) on terminal lug TL174 (12).
(8) Remove nut (13), lockwasher (14), and terminal lug
TL174 (12) from reverse polarity relay 12V LOAD
terminal (15). Discard lockwasher.
20-274