19-22. M1090/M1094 FOUR-WAY RELIEF VALVE SOLENOID REPLACEMENT (CONT)
(6) Position drain pan under four-way relief valve (4).
(7) Remove four screws (7) and solenoid valve (8)
from four-way relief valve (4).
(8) Remove four preformed packings (9) from four-
way relief valve (4). Discard preformed packings.
b. Installation.
(1) Install four preformed packings (1) on four-way relief
valve (2).
(2) Position solenoid valve (3) on four-way relief valve
(2) with four screws (4).
(3) Tighten four screws (4) to 45-55 lb-in. (5-6 Nm).
(4) Install gasket (5) on connector L9 (6).
(5) Connect connector L9 (6) to four-way relief valve
(2).
19-120