TM 9-2320-366-20-5
18-9. PERSONNEL HEATER REPLACEMENT/REPAIR (CONT)
CAUTION
Ensure clamp tongue is started in clamp
groove. Failure to comply may result in
damage to equipment.
(19) Position clamp (23) on heater outlet hose (2).
(20) Position clamp (23) on heater inlet hose (3).
NOTE
Heater outlet hose is marked with an
arrow pointing down.
(21) Position heater outlet hose (2) on return fitting
(27).
NOTE
Heater inlet hose is marked with an arrow
pointing up.
(22) Position heater inlet hose (3) on supply fitting
(28).
(23) Engage as many clamp tabs (25) as possible in
tab windows (26) allowing little or no play between
clamps (23) and heater outlet hose (2) and heater
inlet hose (3).
(24) Tighten two clamps (23) to 8-9 lb-in. (0.9-1 Nm).
NOTE
Minimum allowable gap between ends
of clamp is 0.1 in. (0.3 cm). If gap is
less than 0.1 in. (0.3 cm), remove and
re-install clamp.
(25) Measure gap between ends of two clamps (23).
Change 2