TM 9-2320-366-20-4
7-88. M1084/M1086 BOOM UP SOLENOID CABLE REPLACEMENT (CONT)
b. Installation.
(1) Position boom up solenoid cable (1) through clamp (2).
(2) Position boom up solenoid cable (1) through
compression nut (3), washer (4), and connector (5).
(3) Install washer (4) and compression nut (3) on connector
(5).
(4) Tighten nut (6) on clamp (2).
(5) Install quick disconnect terminal (7) on black wire (8).
(6) Install terminal lug (9) on white wire (10).
(7) Install quick disconnect terminal (7) on ground strip (11)
position 7.
(8) Install terminal lug (9) on terminal block (12) position 21
with screw (13).
(9) Apply varnish to quick disconnect terminal (7) and
terminal lug (9).
7-444