TM 9-2320-272-24-1
Table 2-3. Electrical Troubleshooting (Contd).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Check starter solenoid operation.
Step 1. Turn starter switch to START position and listen for starter solenoid to engage.
a. If thump of starter solenoid energizing is heard, perform malfunction 7.
b. If thump of starter solenoid is not heard, proceed to step 2.
Step 2. Set multimeter to 50-volt range.
Step 3. Connect multimeter positive lead to starter solenoid terminal lead 74 and negative lead
to starter ground as shown.
Step 4. Turn starter switch to START position and observe multimeter for a 24-volt reading.
a. If battery voltage is not indicated, perform malfunction 7.
b. If battery voltage is indicated, replace starter (para. 3-82).
END OF TESTING!
2-102