TM 9-2320-260-34-2
15-91. BLACKOUT AND EMERGENCY LIGHT FIXTURES RELACEMENT
THIS TASK COVERS:
a. Removal
b. Installation
INITIAL SETUP
REFERENCES (TM)
APPLICABLE MODELS
TM 9-2320-260-10
M820, M820A2
TM 9-2320-260-20
TEST EQUIPMENT
TM 9-2320-260-34P-2
EQUIPMENT CONDITION
TOOLS
q External power source disconnected
(TM 9-2320-260-10).
General mechanic's tool kit
q Battery ground cable disconnected
(TM 9-2320-260-20).
q Emergency and blackout lamps removed
(TM 9-2320-260-20).
NOTE
Tag wires; cables, and leads for installation.
1. Remove four screws (7) and housing (6) from van ceiling (3).
2. Remove four screws (1), two jumper cables (5), and wiring harness leads (2) and (4) from housing (6).
1. Install two jumper cables (5) and wiring harness leads (2) and (4) on housing (6) with four
screws (1).
2. Install housing (6) on van ceiling (3) with four screws (7).
FOLLOW-ON TASKS: q Install emergency and blackout lamps (TM 9-2320-260-20).
q Connect battery ground cable (TM 9-2320-260-20).
q Connect external power source (TM 9-2320-260-10).
15-333