TM 9-2320-260-34-2
15-56. LIFTGATE AUXILIARY PUMP AND BRACKET REPLACEMENT (M820A2)
THIS TASK COVERS:
b. Installation
a. Removal
INITIAL SETUP
REFERENCES (TM)
APPLICABLE MODELS
LO 9-2320-260-12
M820A2
TM 9-2320-260-10
TOOLS
TM 9-2320-260-20
General mechanic's tool kit
TM 9-2320-260-34P-2
EQUIPMENT CONDITION
MATERIALS/PARTS
Battery ground cable disconnected
(TM 9-2320-260-20).
Drain hydraulic system (LO 9-2320-260-12).
CAUTION
Clean area around hoses and lines before removal to prevent
q
entry of dirt. Damage will occur if dirt or dust enters system.
q Cap or plug all openings immediately after disconnecting lines
NOTE
q Tag all wires and hydraulic lines for installation.
q Have drainage container ready to catch hydraulic oil.
1. Disconnect hydraulic hoses (8) and (10) from elbows (7) and (9).
2. Remove elbows (7) and (9) from auxiliary pump (5).
3. Remove four screws (1), terminal cover (2), and gasket (3) from auxiliary pump (5).
4. Remove three nuts (23), washers (22), and wires (18) from terminal studs (4).
5. Loosen jamnut (20) and remove wiring insulator (19) and washer (21) from auxiliary pump (5).
6. Remove four nuts (16), Iockwashers (17), screws (6), and auxiliary pump (5) from mounting
bracket (14). Discard Iockwashers (17).
7. Remove four nuts (11), Iockwashers (12), screws (15), and mounting bracket ( 14) from frame (13).
Discard Iockwashers (12).
b. Installation
1. Install mounting bracket (14) on frame (13) with four screws (15), new Iockwashers (12), and
nuts (11).
2. Install auxiliary pump (5) on mounting bracket (14) with four screws (6), new Iockwashers ( 17),
and nuts (16).
3. Install washer (21) on wiring insulator (19), and connect wiring insulator (19) to auxiliary pump (5).
Tighten jamnut (20).
15-214