TM 9-2320-260-34-1
3-50. CYLINDER LINERS AND CYLINDER BLOCK MAINTENANCE (Contd)
c. Cleaning and Inspection
WARNING
Drycleaning solvent is flammable and will not be used near open
flame. Use only in well-ventilated places. Failure to do so may
result in injury to personnel.
1.
For general cleaning instructions, refer to para. 2-8.
2.
Using brushes, clean all oil passages (17).
WARNING
Compressed air source will not exceed 30 psi (207 kPa). When
cleaning with compressed air, eyeshields must be worn. Failure to
wear eyeshields may result in injury to personnel.
3.
Clean all oil passages (17) with compressed air.
3-139