TM 9-2320-260-20
14-9. PERSONNEL HEATER DIVERTER REPLACEMENT
THIS TASK COVERS:
a. Removal
b. Installation
INITIAL SETUP
APPLICABLE MODELS
EQUIPMENT CONDITION
All
Parking brake set (TM 9-2320-260-10).
q
Hood raised and secured (TM 9-2320-260-10).
MATERIALS/PARTS
Personnel heater ducts removed (para. 14-8).
Eight lockwashers
REFERENCES (TM)
TM 9-2320-260-10
TM 9-2320-260-20P
NOTE
The diverter is replaced the same way for the fuel burning
personnel heater kit. This procedure covers the hot water heater
kit only.
1. Remove screw (11), clamp (10), nut (8), and control cable (1) from diverter (9) and arm (12).
2. Remove screw (6), clamp (7), nut (3), and control cable (2) from diverter adapter (4) and arm (5).
NOTE
Assistant will help with steps 3 and 4.
3. Remove two nuts (16). screws (17), four lockwashers (15), and diverter adapter (4) from firewall (13).
Discard lockwashers (15).
4. Remove four nuts (14), screws 19), lockwashers (18), and diverter (9) from firewall (13). Discard
lockwashers (18).
NOTE
Assistant will help with steps 1 and 2.
1. Install diverter (9) on firewall (13) with four new lockwashers (18), screws (19), and nuts (14).
2. Install diverter adapter (4) on firewall (13) with four new lockwashers (15), two screws (17), and
nuts (16).
3. Install control cable (2) on arm (5) and diverter adapter (4) with nut (3), clamp (7), and screw (6).
4. Install control cable (1) on arm (12) and diverter (9) with nut (8), clamp (10), and screw (11).
14-16